Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
2.
Neurogastroenterol Motil ; 34(4): e14227, 2022 Apr.
Article in English | MEDLINE | ID: covidwho-1338094

ABSTRACT

BACKGROUND: Aerosol spread is key to interpret the risk of viral contamination during clinical procedures such as esophageal high-resolution manometry (HRM). Installing an air purifier seems a legitimate strategy, but this has recently been questioned. METHODS: Patients undergoing an HRM procedure at the Leuven University Hospital were included in this clinical study. All subjects had to wear a surgical mask which was only lowered beneath the nose during the placement and removal of the nasogastric catheter. The number of aerosol particles was measured by a Lasair® II Particle Counter to obtain data about different particles sizes: 0.3; 0.5; 1.0; 3.0; 5.0; and 10.0 µm. Measurements were done immediately before the placement and the removal of the HRM catheter, and one and 5 min after. A portable air purifier with high-efficiency particle air filters was installed in the hospital room. KEY RESULTS: Thirteen patients underwent a manometry examination. The amount of 0.3 µm-sized particles was unaffected during the whole procedure. The larger particle sizes (1.0; 3.0; 5.0; and 10.0 µm) decreased when the catheter was positioned, but not 0.5 µm. During the HRM measurements itself, these numbers decreased further. Yet, 1 min after catheter removal a significant elevation of particles was seen, which did not recover within 5 min. CONCLUSIONS & INTERFERENCES: Based on this study, there is no evidence that filtration systems reduce aerosol particles properly during a clinical investigation.


Subject(s)
Air Filters , COVID-19 , Aerosols , Humans , Particle Size
4.
J Clin Med ; 9(10)2020 Oct 01.
Article in English | MEDLINE | ID: covidwho-905969

ABSTRACT

BACKGROUND: The new coronavirus disease (COVID-19) has high infection and mortality rates, and has become a pandemic. The infection and mortality rates are lower in Asian countries than in European countries. This study aimed to conduct a survey on the effects of COVID-19 on the capacity to perform gastrointestinal motility tests in Asian countries compared with European countries. METHODS: We used the questionnaire previously established by our team for researchers in European countries. The correlation between the decreased rate of gastrointestinal motility and function tests, and the infection/mortality rates of COVID-19 and stringency of a government's interventions in each country was analysed and protective measures were assessed. RESULTS: In total, 58 gastroenterologists/motility experts in Asian countries responded to this survey. The infection/mortality rates of COVID-19 and Stringency Index had a significant impact on the testing capacity of oesophageal manometry and catheter-based pH monitoring. In European countries, most facilities used filtering facepiece 2/3 (FFP2/3) masks during oesophageal motility studies. Meanwhile, in Asian countries, most facilities used surgical masks. CONCLUSION: The total infection and mortality rates of COVID-19 can affect the rate of gastrointestinal motility testing and the type of protective equipment that must be used.

5.
Neurogastroenterol Motil ; 32(7): e13926, 2020 07.
Article in English | MEDLINE | ID: covidwho-457062

ABSTRACT

BACKGROUND: The COVID-19 pandemic, declared by WHO on March 13, 2020, had a major global impact on the healthcare system and services. In the acute phase, the presence of the SARS-CoV-2 virus in the aerodigestive tract limited activities in the gastroenterology clinic and procedures to emergencies only. Motility and function testing was interrupted and as we enter the recovery phase, restarting these procedures requires a safety-focused approach with adequate infection prevention for patients and healthcare professionals. METHODS: We summarized knowledge on the presence of the SARS-CoV-2 virus in the aerodigestive tract and the risk of spread with motility and functional testing. We surveyed 39 European centers documenting how the pandemic affected activities and which measures they are considering for restarting these measurements. We propose recommendations based on current knowledge as applied in our center. RESULTS: Positioning of catheters for gastrointestinal motility tests carries a concern for aerosol-borne infection of healthcare workers. The risk is low with breath tests. The surveyed centers stopped almost all motility and function tests from the second half of March. The speed of restarting and the safety measures taken varied highly. CONCLUSIONS AND INFERENCES: Based on these findings, we provided recommendations and practical relevant information for motility and function test procedures in the COVID-19 pandemic era, to guarantee a high-quality patient care with adequate infection prevention.


Subject(s)
Betacoronavirus , Coronavirus Infections/epidemiology , Gastroenterology/methods , Gastrointestinal Motility/physiology , Pandemics , Pneumonia, Viral/epidemiology , Recovery of Function/physiology , COVID-19 , Coronavirus Infections/prevention & control , Europe/epidemiology , Gastroenterology/standards , Health Personnel/standards , Humans , Pandemics/prevention & control , Patient Care/methods , Patient Care/standards , Pneumonia, Viral/prevention & control , Practice Guidelines as Topic/standards , Protective Clothing/standards , SARS-CoV-2 , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL